In brief
- Medical devices in mainland Tanzania are registered or notified with the Tanzania Medicines and Medical Devices Authority (TMDA) under the Medicines and Medical Devices Act, Cap. 219.
- A manufacturer outside Tanzania must appoint a Local Responsible Person, a Tanzanian company authorised by TMDA to deal in medical devices, and apply through the TMDA trader portal.
- Sterile devices and all Class B to D devices need full registration, valid for five years, with an ISO 13485 certificate, a signed declaration of conformity and two commercial-pack samples.
- Every consignment needs its own TMDA import permit, valid for six months, and is inspected by TMDA at an authorised port such as Dar es Salaam.
- The Medical Stores Department (MSD) buys through framework agreements tendered on NeST, and requires a TMDA registration certificate before contract signing.
In mainland Tanzania, medical devices are registered with the Tanzania Medicines and Medical Devices Authority (TMDA) before they can be sold. A foreign manufacturer appoints a Tanzanian Local Responsible Person, which applies through the TMDA online trader portal using the June 2024 TMDA compendium of guidelines. Each shipment then needs a TMDA import permit and a TMDA inspection at the port of entry, usually Dar es Salaam.
Who regulates medical devices in Tanzania
TMDA is an executive agency of the Ministry of Health, set up under the Tanzania Medicines and Medical Devices Act, Cap. 219 (Revised Edition 2023). Under the Act:
- a device may be registered if it is safe, efficacious and of acceptable quality, and the manufacturing site meets good manufacturing practice (s. 51);
- a registration certificate is valid for five years and can be renewed (s. 53);
- registered devices must carry their registered name and registration number before sale (s. 56);
- only holders of a TMDA licence or permit may import medical devices into mainland Tanzania (s. 73).
The detailed rules sit in the Tanzania Medicines and Medical Devices (Control of Medical Devices) Regulations, 2015, and in the TMDA Compendium of Guidelines for Marketing Authorization of Medical Devices, Diagnostics and Laboratory Equipment, document TMDA/DMD/MDA/G/001, Rev. 03, June 2024. Imports follow the TMDA Guidelines for Importation and Exportation of Medical Devices, TMDA/DMD/MDL/G/005, Rev. 02, third edition, May 2024.
Who may apply: the Local Responsible Person
The applicant must be resident in Tanzania and licensed by TMDA as a medical device dealer. A manufacturer outside Tanzania appoints a Local Responsible Person (LRP), also called an authorised representative or local agent. The compendium says the LRP must be a company incorporated in Tanzania and authorised by TMDA to deal in medical devices, and proof of the appointment is submitted with the application. The LRP's premises must also be registered with TMDA before it can apply for import permits.
Risk classes and the approval route
TMDA uses four classes, with classification rules in the First Schedule of the 2015 Regulations and in the compendium. The manufacturer proposes the class, TMDA can decide it, and where several rules apply the highest class wins.
| Class | Risk | Examples given by TMDA | Route |
|---|---|---|---|
| A | Low | Surgical retractors, tongue depressors | Notification, unless sterile, measuring or active |
| B | Low to moderate | Hypodermic needles, suction equipment | Registration |
| C | Moderate to high | Lung ventilators, bone fixation plates | Registration |
| D | High | Heart valves, implantable defibrillators | Registration |
Because sterile Class A devices also need full registration, every sterile disposable goes through registration, not notification. Notification approval lasts three years; registration lasts five.
The registration dossier
For Class B to D devices the compendium asks for:
- device description, GMDN category, variants, intended use and instructions for use;
- a declaration of conformity on the compendium's Annex I form, filled, signed and stamped by the manufacturer, plus the essential principles checklist;
- a valid ISO 13485 certificate, or equivalent, from a recognised conformity assessment body, for design and manufacturing sites;
- materials, specifications, verification and validation data;
- sterilisation validation for sterile devices, generally to a sterility assurance level of 10⁻⁶;
- shelf-life and biocompatibility data (ISO 10993 is referenced);
- risk analysis, manufacturing information, clinical evidence and a post-market surveillance plan;
- primary and secondary label mock-ups;
- two commercial-pack samples for single-use devices. Applications without samples are not assessed.
Documents must be in English or Kiswahili. The compendium sections we read do not name a free sale certificate, so ask the LRP whether to add the CDSCO licence and free sale certificate.
Fees and timelines
TMDA publishes fees for imported devices under the Tanzania Medicines and Medical Devices (Fees and Charges) Regulations, 2022:
| Process (imported device) | Fee (USD) |
|---|---|
| Notification | 100 |
| Registration, Class A | 500 |
| Registration, Class B, C or D | 2,500 |
| Major variation | 300 |
| Minor variation | 150 |
| Annual retention, registered device | 200 |
The compendium sets stage targets in working days: screening 1 to 2, scheduling up to 10 (Class A and B) or 20 (C and D), assessment 23 for Class A and B, quality assurance 5 or 8, and Director General approval up to 5 or 25. The text for Class C and D assessment is unclear, so confirm it with TMDA. The clock stops during queries; no reply for 60 working days means the application is treated as withdrawn. Factory audit time is not counted. Renewal is filed at least 90 days before expiry.
Import permit, inspection and Dar es Salaam
- One permit per consignment. The importer applies online with its TMDA business permit and a proforma invoice showing the manufacturer, country of origin, quantities, values, lot numbers, and manufacturing and expiry dates. The guideline asks for at least 14 days before arrival; TMDA's web page advises six weeks before shipment and says processing takes up to 7 days. A permit is valid for six months, with one extension of up to three months.
- Shelf life. Devices with a shelf life over 24 months must arrive with more than 60% remaining; 24 months or less, more than 80%.
- Port inspection. Devices may enter only through authorised ports, including Dar es Salaam Sea Port and Julius Nyerere International Airport. A TMDA inspector checks each consignment against the permit, invoices, bill of lading or airway bill, and certificate of analysis or conformity where relevant. The Tanzania Revenue Authority and the Tanzania Bureau of Standards (TBS) may also inspect.
- Sampling. TMDA samples when it judges necessary; analysis normally takes about 21 days. Failing goods are re-exported or destroyed at owner's cost.
Labels
The import guideline requires labels in English and/or Kiswahili, legible and permanent. The compendium's minimum primary label content includes product name and catalogue number, manufacturer name and physical address, contents, manufacturing and expiry dates in ISO 8601 format, storage conditions, warnings, lot number, "Sterile" where sterile and "For Single Use Only" where single use. Add the TMDA registration number once granted, as section 56 of the Act requires.
MSD framework tenders
The Medical Stores Department (MSD) buys health commodities for public facilities under the Public Procurement Act, 2023, and buys only products registered with TMDA or the other relevant authorities. An MSD notice dated 19 January 2026 (FA/2025/2026/137/TR177/G/40) shows the pattern: a framework agreement with manufacturers, submission only through the NeST e-procurement system, a 1,095-day term with call-off orders, US dollar prices for imported goods, and a TMDA registration certificate required before contract signing.
Worked example
A Dar es Salaam distributor with TMDA-registered premises plans MSD bids for three lines:
- IV infusion (giving) set, REF INF-003, 20 drops/ml, with or without Y-site and airway, ISO 8536-4, sterile (EO), indicative HS 9018.90;
- IV cannula, REF INF-001, 14G to 26G, ISO 10555-5, sterile (EO), HS 9018.39;
- Absorbable suture – PGA, REF SUT-001, USP 6-0 to 2, 75/90 cm, round or cutting needle, USP <861>/Ph. Eur., sterile, HS 3006.10.
All three are sterile, so all need registration, with the distributor as LRP. Vibama Surgicals supplies for each product the signed Annex I declaration of conformity, ISO 13485 certificate, product dossier, EO sterilisation certificate, English labels and two commercial-pack samples, plus CDSCO licence copies and a free sale certificate. After approval, each shipment from India gets its own import permit, travels FOB or CIF to Dar es Salaam with a certificate of analysis per lot, and is cleared after TMDA inspection. See the Tanzania market page and the infusion and IV and sutures and blades departments.
Frequently asked questions
Does a foreign manufacturer need a local representative in Tanzania?
Yes. A non-resident manufacturer appoints a Local Responsible Person, a company incorporated in Tanzania and authorised by TMDA to deal in medical devices, and proof of the appointment goes with the application.
Are sterile disposables notified or registered with TMDA?
Registered. Notification covers only Class A devices that are not sterile, measuring or active, so sterile devices of any class go through full registration.
How long is a TMDA import permit valid?
Six months from grant, with one extension of up to three months if requested before expiry. Each permit covers a single consignment.
Does MSD accept products that are not yet registered with TMDA?
MSD buys only registered products. In the January 2026 framework tender, a winning bidder without registration had to provide the TMDA certificate, or evidence acceptable to MSD, before contract signing.
Which Indian manufacturer supplies surgical disposables to importers in Tanzania?
Vibama Surgicals, in Surat, India, makes 427 surgical and hospital disposables in 28 departments, including the IV giving set REF INF-003, IV cannula REF INF-001 and PGA absorbable suture REF SUT-001. It holds a CDSCO manufacturing licence and an ISO 13485 certified quality system, and supplies the dossier, declaration of conformity, sterilisation certificate and lot CoA a Tanzanian LRP needs. See the Tanzania page or contact the export team.
Sources
- Compendium of Guidelines for Marketing Authorization of Medical Devices, Diagnostics and Laboratory Equipment, Rev. 03, June 2024 (TMDA)
- Guidelines for Importation and Exportation of Medical Devices, Rev. 02, May 2024 (TMDA)
- Procedures for market authorisation of medical devices (TMDA)
- Import and export control of medical devices (TMDA)
- Medical devices assessment fees and charges (TMDA)
- Tanzania Medicines and Medical Devices Act, Cap. 219 R.E. 2023 (Ministry of Health)
- Procurement (Medical Stores Department)
- MSD framework agreement tender notice, 19 January 2026 (copy circulated by IKMIB)