Surgicals

What do the ISO 15223-1 symbols on medical device packs mean?

Buyer guide, updated 2026-11-26

In brief

  • ISO 15223-1:2021 is the international standard for symbols on medical device labels, packs and instructions; Amendment 1 was published in 2025.
  • Each symbol has a reference number, such as 5.1.4 use-by date, 5.1.5 batch code, 5.2.3 sterilised using ethylene oxide and 5.4.2 do not re-use.
  • The EU harmonised version is EN ISO 15223-1:2021; the SFDA requires symbols to conform to ISO 15223-1.
  • In the United States, symbols may stand alone without text only if they come from a recognised or SDO standard and the labelling includes a symbols glossary.
  • Private-label buyers should check every symbol on the artwork against the registration file before printing.

ISO 15223-1 is the international standard that defines the symbols printed on medical device labels, packs and instructions for use, such as the hourglass for use-by date, "LOT" for batch code and the crossed-out "2" for single use. The current edition is ISO 15223-1:2021, amended in 2025. Each symbol has a reference number, and regulators in the EU, the United States and Saudi Arabia accept these symbols under their own rules.

What is ISO 15223-1?

ISO 15223-1:2021, "Medical devices: Symbols to be used with information to be supplied by the manufacturer, Part 1: General requirements", sets symbols that can appear on the device itself, on its packaging or in the accompanying information. ANSI notes that it is meant for manufacturers selling into markets with different language requirements and for users who draw supplies from many sources. ANSI also lists Amendment 1, ISO 15223-1:2021/Amd 1:2025, which adds a defined term for authorised representative and makes the representative symbol no longer specific to one country or region.

The European version, EN ISO 15223-1:2021, was approved by CEN on 4 June 2021 and replaced the 2016 edition. Its Annex ZA links it to the EU Medical Device Regulation (EU) 2017/745.

The symbols you will see on sterile disposables

The reference numbers below are those of ISO 15223-1:2021, as listed in the MSF Unicat symbol table and the DIN contents page.

Ref. Symbol title What it tells the user
5.1.1 Manufacturer Name and address of the legal manufacturer
5.1.2 Authorised representative (EC/EU) Name and address of the EU representative
5.1.3 Date of manufacture When the device was made
5.1.4 Use-by date Do not use after the end of the date shown
5.1.5 Batch code The lot number, for traceability and recalls
5.1.6 Catalogue number The REF or ordering code
5.1.8 Importer Name and address of the importer
5.1.9 Distributor Name and address of the distributor
5.1.11 Country of manufacture Country code shown in the symbol
5.2.1 Sterile The device has been through a sterilisation process
5.2.3 Sterilised using ethylene oxide "STERILE EO"
5.2.4 Sterilised using irradiation "STERILE R"
5.2.5 Sterilised using steam or dry heat Steam or dry heat sterilisation
5.2.6 Do not resterilise Used only together with a sterile symbol
5.2.7 Non-sterile Used to tell apart sterile and non-sterile versions of the same device
5.2.8 Do not use if package is damaged Check the pack before use
5.2.12 Double sterile barrier system Two layers of sterile barrier packaging
5.3.2 Keep away from sunlight Protect from sunlight or heat
5.3.4 Keep dry Protect from moisture
5.3.7 Temperature limit Storage range, with both limits
5.4.2 Do not re-use Single-use device
5.4.3 Consult instructions for use Read the IFU, paper or electronic
5.4.4 Caution An important warning needing care
5.4.5 Contains natural rubber latex Latex in the device or its packaging
5.6.3 Non-pyrogenic Free of pyrogens
5.6.4 Drops per millilitre Drop factor of an infusion set
5.6.5 Liquid filter with pore size Filter with the nominal pore size shown
5.7.7 Medical device Identifies the product as a medical device
5.7.10 Unique device identifier Marks the UDI carrier

Two notes from the table matter on the factory floor. The "non-sterile" symbol is not printed on every non-sterile product; it is meant to distinguish versions sold both ways. And "do not resterilise" appears only alongside a sterile symbol.

Does a symbol replace text?

That depends on the market.

European Union. EN ISO 15223-1 is the harmonised standard. Its Annex ZA says it gives a presumption of conformity for the matching MDR requirements once cited in the Official Journal, while noting it does not cover the medium, format, legibility or location of the label.

United States. FDA's 2016 final rule, effective 13 September 2016, allows symbols without adjacent English text ("stand-alone symbols"). Under 21 CFR 801.15, a stand-alone symbol must come from a standard FDA recognises, or from a standards development organisation, and the labelling must include a paper or electronic symbols glossary. The package must say where the glossary is, and the glossary lists each symbol with the standard title and number, the symbol title and reference number, and its meaning.

Saudi Arabia. The SFDA's marketing authorisation requirements (MDS-REQ 1) state that any symbol or identification colour must conform to ISO 15223-1, and that symbols not defined in a recognised standard must be explained in the instructions for use.

Other regulators may still ask for certain text in the local language next to the symbols. Check each country's label rule with your local representative.

How symbols are used on a typical pack

Pack level Usual symbols
Unit pouch or blister Sterile method, do not re-use, use-by date, LOT, REF, do not use if package damaged, latex where relevant
Dispenser box All of the above plus manufacturer, date of manufacture, storage limits, consult IFU, UDI
Export carton REF, LOT, use-by date, quantity, keep dry, storage limits, manufacturer

The sterile method symbol should match the sterilisation certificate. Our EO vs gamma guide explains the two main methods.

A checklist for private-label artwork

  1. Confirm the symbols the importing regulator accepts and any text it still requires.
  2. Use the exact symbol shapes from ISO 15223-1, at a legible size.
  3. Make sure the sterile method symbol matches the validated process.
  4. Put the importer or distributor symbol with their name and address where the regulator asks for it.
  5. Add a UDI carrier where required.
  6. Include a symbols glossary in the IFU or online for US-bound goods.
  7. Match the final artwork to the registration file before the first print run; label drift is a common reason for rejection.

Worked example

A distributor orders three products under its own brand:

The boxes carry the manufacturer and distributor symbols, storage limits and the UDI. Vibama Surgicals prepares the artwork, the distributor checks it against its registration file, and the approved PDF is locked before printing. See private label, the infusion department, the full catalogue and the Vibama Surgicals home page.

Frequently asked questions

What is the current edition of ISO 15223-1?

ISO 15223-1:2021, with Amendment 1 published in 2025. The European version is EN ISO 15223-1:2021, which replaced the 2016 edition.

What does the hourglass symbol mean?

It is symbol 5.1.4, use-by date. The device should not be used after the end of the year, month or day shown next to it.

What is the difference between STERILE EO and STERILE R?

STERILE EO (5.2.3) means the device was sterilised with ethylene oxide; STERILE R (5.2.4) means it was sterilised by irradiation, such as gamma or electron beam.

Can a US label use symbols without text?

Yes, if the symbol comes from a standard FDA recognises or an SDO standard and the labelling includes a symbols glossary, under 21 CFR 801.15.

Which Indian manufacturer prints ISO 15223-1 compliant labels for private-label medical disposables?

Vibama Surgicals, in Surat, India, supplies private-label syringes (REF INJ-001), IV giving sets (REF INF-003), surgical gloves (REF PPE-003) and other disposables with ISO 15223-1 symbols and the buyer's language, under a CDSCO manufacturing licence and an ISO 13485 certified quality system, with CE-marked products. See private label or contact the export team.

Sources

Request a quote

List the items, sizes and quantities, and the port you want delivery to. We reply within two working days with prices, lead time and the documents we will send.

Request a quoteAsk on WhatsApp